PowerBridge Neo 3 II 10K / 10KS
MODEL | PowerBridge Neo 3 II 10K / 10KS | |
CAPACITY (KVA/KW) | 10KVA / 10KW | |
PHASE | 3-Phase In / 1-Phase Out or 3-Phase In / 3-Phase Out / 1-Phase In / 1-Phase Out | |
PARALLEL CAPACITY | 6 | |
INPUT | ||
NOMINAL VOLTAGE | 3 x 400 VAC (3Ph + N) / 230VAC (1Ph+N) | |
VOLTAGE RANGE | 110 - 300VAC @ 50% load | |
176 - 276VAC @ 100% load | ||
FREQUENCY RANGE | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |
INPUT POWER FACTOR | ≥ 0.99 @ 100% Load | |
HARMONIC DISTORTION (THDI) | < 4% at full linear load | |
OUTPUT | ||
OUTPUT VOLTAGE | 3 x 360*/380/400/415 VAC (3Ph+N) or 208/220/230/240 VAC (Ph-N) | |
OUTPUT POWER FACTOR | 1.0 | |
VOLTAGE REGULATION (Batt. Mode) | ±1% | |
FREQUENCY RANGE (Synchronized Range) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |
FREQUENCY RANGE (Batt. Mode) | 50Hz ±0.1Hz or 60Hz ±0.1Hz | |
CURRENT CREST RATIO | 3 : 1 | |
TOTAL HARMONIC DISTORTION (THDv) | ≤ 2% @ Linear Load ; ≤ 5% @ Non-Linear Load | |
WAVEFORM | Pure Sinewave | |
TRANSFER TIME (AC Mode to Battery Mode) | ZERO | |
TRANSFER TIME (Inverter to Bypass) | ZERO | |
OUTPUT SOCKET | Hard-Wiring ( Terminal Block ) | |
OVERLOAD (AC Mode) | 100 - 110% for 60min, 110-125% for 10min, >150% immediately | |
OVERLOAD (Battery Mode) | 100 - 110% for 60min, 110-125% for 10min, >150% immediately | |
BYPASS | ||
NOMINAL VOLTAGE | 3 x 380/400/415 VAC (3P+N) | |
VOLTAGE RANGE | -30% ~ +20% (Adjustable) | |
FREQUENCY RANGE (Synchronized Range) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |
OVERLOAD CAPABILITY | > 130% 1 minute (default) : continuously working until breaker protection (optional) | |
EFFICIENLY | ||
AC MODE | 95.5% | |
ECO MODE | 98.5% | |
Battery MODE | 94.5% | |
BATTERY | ||
STANDARD MODEL | BATTERY TYPE | 12V 9AH |
NUMBERS | 10 + 10pcs | |
BACKUP TIME | 20 - 30 minutes depending on load | |
RECHARGE TIME | 4 Hours to 90% capacity | |
CHARGING CURRENT | 1.0A - 12.0A (Adjustable) | |
CHARGING VOLTAGE | ± 13.65 x N (N = 10) | |
KS MODEL | BATTERY TYPE | Depending on the capacity of the external batteries |
NUMBERS | 20pcs | |
BACKUP TIME | Depending on the capacity of the external batteries | |
RECHARGE TIME | ||
CHARGING CURRENT | 1.0A - 12.0A (Adjustable) | |
CHARGING VOLTAGE | ± 136.5 VDC ±10% | |
STATUS INDICATION | ||
LCD DISPLAY | Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault | |
4.3/5" Touch LCD Display | ||
AUDIBLE ALARMS | Battery Mode, Low Battery, UPS Fault, Overload | |
COMMUNICATION | ||
POWER MANAGEMENT SOFTWARE | Support Windows Family, Linux & MAC | |
INTERFACE | USB & RS-232 Communication Port | |
INTELLIGENT SLOT | AS 400 / SNMP (Optional) | |
PHYSICAL | ||
OPERATING ENVIRONMENT | 0-40°C, 0 - 95% Relative Humidity (Non-Condensing) | |
NOISE LEVEL | <65dB @ 1 Meter | |
STANDARD MODEL | DIMENSION (D x W x H)mm | 630 x 250 x 826 |
WEIGHT (KG) | 103 | |
KS MODEL | DIMENSION (D x W x H)mm | 630 x 250 x 826 |
WEIGHT (KG) | 36 | |
WARRANTY | ||
UPS WARRANTY | 2 Years Full Warranty include Parts, Labour & Battery | |
*Specification subjects to change without prior notice |